Test Name |
Test Description |
Observation |
---|---|---|
4.1.13.1.2.1 CommEn Input threshold |
Determine the wake-up threshold of the DUT |
|
4.1.13.1.2.1.1 CommEn Input thrshld 6V |
Activate the Communication Enable Line. Increase the amplitude of the Communication Enable Line in useful steps starting from 0 V to 6V |
Acceptance Criteria: The DUT shall wake up if the input threshold is within the following range: 4.5 V <= Vwu <= 26.5 V. Once active, the DUT shall enter SleepMode if Vwu<=2.0 V. The DUT shall not wake up if the input threshold Vwu is < 4.5 V. |
4.1.13.1.2.1.2 CommEn Input thrshld 9V |
Activate the Communication Enable Line. Increase the amplitude of the Communication Enable Line in useful steps starting from 0 V to 9V |
Acceptance Criteria: The DUT shall wake up if the input threshold is within the following range: 4.5 V <= Vwu <= 26.5 V. Once active, the DUT shall enter SleepMode if Vwu<=2.0 V. The DUT shall not wake up if the input threshold Vwu is < 4.5 V. |
4.1.13.1.2.1.3 CommEn Input thrshld 12V |
Activate the Communication Enable Line. Increase the amplitude of the Communication Enable Line in useful steps starting from 0 V to 12V |
Acceptance Criteria: The DUT shall wake up if the input threshold is within the following range: 4.5 V <= Vwu <= 26.5 V. Once active, the DUT shall enter SleepMode if Vwu<=2.0 V. The DUT shall not wake up if the input threshold Vwu is < 4.5 V. |
4.1.13.1.2.1.4 CommEn Input thrshld 16V |
Activate the Communication Enable Line. Increase the amplitude of the Communication Enable Line in useful steps starting from 0 V to 16V |
Acceptance Criteria: The DUT shall wake up if the input threshold is within the following range: 4.5 V <= Vwu <= 26.5 V. Once active, the DUT shall enter SleepMode if Vwu<=2.0 V. The DUT shall not wake up if the input threshold Vwu is < 4.5 V. |
4.1.13.1.2.1.5 CommEn Input thrshld 18V |
Activate the Communication Enable Line. Increase the amplitude of the Communication Enable Line in useful steps starting from 0 V to 18V |
Acceptance Criteria: The DUT shall wake up if the input threshold is within the following range: 4.5 V <= Vwu <= 26.5 V. Once active, the DUT shall enter SleepMode if Vwu<=2.0 V. The DUT shall not wake up if the input threshold Vwu is < 4.5 V. |
4.1.13.1.2.1.6 CommEn Input thrshld 26.5V |
Activate the Communication Enable Line. Increase the amplitude of the Communication Enable Line in useful steps starting from 0 V to 26.5V |
Acceptance Criteria: The DUT shall wake up if the input threshold is within the following range: 4.5 V <= Vwu <= 26.5 V. Once active, the DUT shall enter SleepMode if Vwu<=2.0 V. The DUT shall not wake up if the input threshold Vwu is < 4.5 V. |
4.1.13.1.2.2 CommEn Input Successful wake up detection |
Verify that the DUT does not wake up after receiving an invalid wake-up pulse |
|
4.1.13.1.2.2 CommEn Sucsful Wake Up Detection 6.5V Twu 90 |
Verify the DUT WakesUp,when a Transmit a pulse with a duration of 90 µs and an amplitude of 4.5 V on the Communication Enable Line at 6.5V |
Acceptance Criteria: The DUT shall wake up after receiving the wake-up pulse |
4.1.13.1.2.2 CommEn Sucsful Wake Up Detection 6.5V Twu 100 |
Verify the DUT WakesUp,when a Transmit a pulse with a duration of 100 µs and an amplitude of 4.5 V on the Communication Enable Line at 6.5V |
Acceptance Criteria: The DUT shall wake up after receiving the wake-up pulse |
4.1.13.1.2.2 CommEn Sucsful Wake Up Detection 6.5V Twu 2 |
Verify the DUT WakesUp,when a Transmit a pulse with a duration of 2 ms and an amplitude of 4.5 V on the Communication Enable Line at 6.5V |
Acceptance Criteria: The DUT shall wake up after receiving the wake-up pulse |
4.1.13.1.2.2 CommEn Sucsful Wake Up Detection 9V Twu 90 |
Verify the DUT WakesUp,when a Transmit a pulse with a duration of 90 µs and an amplitude of 4.5 V on the Communication Enable Line at 9V |
Acceptance Criteria: The DUT shall wake up after receiving the wake-up pulse |
4.1.13.1.2.2 CommEn Sucsful Wake Up Detection 9V Twu 100 |
Verify the DUT WakesUp,when a Transmit a pulse with a duration of 100 µs and an amplitude of 4.5 V on the Communication Enable Line at 9V |
Acceptance Criteria: The DUT shall wake up after receiving the wake-up pulse |
4.1.13.1.2.2 CommEn Sucsful Wake Up Detection 9V Twu 2 |
Verify the DUT WakesUp,when a Transmit a pulse with a duration of 2 ms and an amplitude of 4.5 V on the Communication Enable Line at 9V |
Acceptance Criteria: The DUT shall wake up after receiving the wake-up pulse |
4.1.13.1.2.2 CommEn Sucsful Wake Up Detection 12V Twu 90 |
Verify the DUT WakesUp,when a Transmit a pulse with a duration of 90 µs and an amplitude of 4.5 V on the Communication Enable Line at 12V |
Acceptance Criteria: The DUT shall wake up after receiving the wake-up pulse |
4.1.13.1.2.2 CommEn Sucsful Wake Up Detection 12V Twu 100 |
Verify the DUT WakesUp,when a Transmit a pulse with a duration of 100 µs and an amplitude of 4.5 V on the Communication Enable Line at 12V |
Acceptance Criteria: The DUT shall wake up after receiving the wake-up pulse |
4.1.13.1.2.2 CommEn Sucsful Wake Up Detection 12V Twu 2 |
Verify the DUT WakesUp,when a Transmit a pulse with a duration of 2 ms and an amplitude of 4.5 V on the Communication Enable Line at 12V |
Acceptance Criteria: The DUT shall wake up after receiving the wake-up pulse |
4.1.13.1.2.2 CommEn Sucsful Wake Up Detection 16V Twu 90 |
Verify the DUT WakesUp,when a Transmit a pulse with a duration of 90 µs and an amplitude of 4.5 V on the Communication Enable Line at 16V |
Acceptance Criteria: The DUT shall wake up after receiving the wake-up pulse |
4.1.13.1.2.2 CommEn Sucsful Wake Up Detection 16V Twu 100 |
Verify the DUT WakesUp,when a Transmit a pulse with a duration of 100 µs and an amplitude of 4.5 V on the Communication Enable Line at 16V |
Acceptance Criteria: The DUT shall wake up after receiving the wake-up pulse |
4.1.13.1.2.2 CommEn Sucsful Wake Up Detection 16V Twu 2 |
Verify the DUT WakesUp,when a Transmit a pulse with a duration of 2 ms and an amplitude of 4.5 V on the Communication Enable Line at 16V |
Acceptance Criteria: The DUT shall wake up after receiving the wake-up pulse |
4.1.13.1.2.3 CommEn Wake-Up Filter Function |
Verify that the DUT does not wake up after receiving an invalid wake-up pulse |
|
4.1.13.1.2.3 CommEn Wake Up Fltr Func 6.5V Twu 90 |
Verify the DUT doesnot WakesUp,when a Transmit a pulse with a duration of 90 µs and an amplitude of 4.5 V on the Communication Enable Line at 6.5V |
Acceptance Criteria: The DUT shall not wake up after sensing a wake-up pulse which is shorter than the wake-up filter time of 100 µs |
4.1.13.1.2.3 CommEn Wake Up Fltr Func 6.5V Twu 100 |
Verify the DUT doesnot WakesUp,when a Transmit a pulse with a duration of 100 µs and an amplitude of 4.5 V on the Communication Enable Line at 6.5V |
Acceptance Criteria: The DUT shall not wake up after sensing a wake-up pulse which is shorter than the wake-up filter time of 100 µs |
4.1.13.1.2.3 CommEn Wake Up Fltr Func 6.5V Twu 2 |
Verify the DUT doesnot WakesUp,when a Transmit a pulse with a duration of 2 ms and an amplitude of 4.5 V on the Communication Enable Line at 6.5V |
Acceptance Criteria: The DUT shall not wake up after sensing a wake-up pulse which is shorter than the wake-up filter time of 100 µs |
4.1.13.1.2.3 CommEn Wake Up Fltr Func 9V Twu 90 |
Verify the DUT doesnot WakesUp,when a Transmit a pulse with a duration of 90 µs and an amplitude of 4.5 V on the Communication Enable Line at 9V |
Acceptance Criteria: The DUT shall not wake up after sensing a wake-up pulse which is shorter than the wake-up filter time of 100 µs |
4.1.13.1.2.3 CommEn Wake Up Fltr Func 9V Twu 100 |
Verify the DUT doesnot WakesUp,when a Transmit a pulse with a duration of 100 µs and an amplitude of 4.5 V on the Communication Enable Line at 9V |
Acceptance Criteria: The DUT shall not wake up after sensing a wake-up pulse which is shorter than the wake-up filter time of 100 µs |
4.1.13.1.2.3 CommEn Wake Up Fltr Func 9V Twu 2 |
Verify the DUT doesnot WakesUp,when a Transmit a pulse with a duration of 2 ms and an amplitude of 4.5 V on the Communication Enable Line at 9V |
Acceptance Criteria: The DUT shall not wake up after sensing a wake-up pulse which is shorter than the wake-up filter time of 100 µs |
4.1.13.1.2.3 CommEn Wake Up Fltr Func 12V Twu 90 |
Verify the DUT doesnot WakesUp,when a Transmit a pulse with a duration of 90 µs and an amplitude of 4.5 V on the Communication Enable Line at 12V |
Acceptance Criteria: The DUT shall not wake up after sensing a wake-up pulse which is shorter than the wake-up filter time of 100 µs |
4.1.13.1.2.3 CommEn Wake Up Fltr Func 12V Twu 100 |
Verify the DUT doesnot WakesUp,when a Transmit a pulse with a duration of 100 µs and an amplitude of 4.5 V on the Communication Enable Line at 12V |
Acceptance Criteria: The DUT shall not wake up after sensing a wake-up pulse which is shorter than the wake-up filter time of 100 µs |
4.1.13.1.2.3 CommEn Wake Up Fltr Func 12V Twu 2 |
Verify the DUT doesnot WakesUp,when a Transmit a pulse with a duration of 2 ms and an amplitude of 4.5 V on the Communication Enable Line at 12V |
Acceptance Criteria: The DUT shall not wake up after sensing a wake-up pulse which is shorter than the wake-up filter time of 100 µs |
4.1.13.1.2.3 CommEn Wake Up Fltr Func 16V Twu 90 |
Verify the DUT doesnot WakesUp,when a Transmit a pulse with a duration of 90 µs and an amplitude of 4.5 V on the Communication Enable Line at 16V |
Acceptance Criteria: The DUT shall not wake up after sensing a wake-up pulse which is shorter than the wake-up filter time of 100 µs |
4.1.13.1.2.3 CommEn Wake Up Fltr Func 16V Twu 100 |
Verify the DUT doesnot WakesUp,when a Transmit a pulse with a duration of 100 µs and an amplitude of 4.5 V on the Communication Enable Line at 16V |
Acceptance Criteria: The DUT shall not wake up after sensing a wake-up pulse which is shorter than the wake-up filter time of 100 µs |
4.1.13.1.2.3 CommEn Wake Up Fltr Func 16V Twu 2 |
Verify the DUT doesnot WakesUp,when a Transmit a pulse with a duration of 2 ms and an amplitude of 4.5 V on the Communication Enable Line at 16V |
Acceptance Criteria: The DUT shall not wake up after sensing a wake-up pulse which is shorter than the wake-up filter time of 100 µs |
4.1.13.4.2.1 CommEn Input Loss of Power Supply |
Check the impact on the wake-up function when the DUT loses its power supply |
|
4.1.13.4.2.1 CommEn Loss of Pwr |
Monitor the CAN & WakeUp line when DUT is Disconnected Powersupply and Re-connected |
Acceptance Criteria: The DUT shall resume normal communication without any operator intervention within 300 ms after the fault is removed |
4.1.13.4.2.2 CommEn Input Loss of Ground Connection |
Check the impact on the wake-up function when the DUT loses its Ground |
|
4.1.13.4.2.2 CommEn Loss of Gnd |
Monitor the CAN & WakeUp line when DUT is Disconnected Ground and Re-connected |
Acceptance Criteria: The DUT shall resume normal communication without any operator intervention within 300 ms after the fault is removed. |
4.1.13.4.2.3 Communication Enable Line Shorted to Ground |
Check the behavior of the DUT in case of a short between the wake-up line and ground |
|
4.1.13.4.2.3 CommEn Short to Gnd |
Monitor the CAN & WakeUp line when short between the communication enable line and ground and Removed the fault |
Acceptance Criteria: The DUT shall resume normal communication without any operator intervention within 300 ms after the fault is removed. |
4.1.13.4.2.4 Communication Enable Line Shorted to Battery |
Check the behavior of the DUT in case of a short between the communication enable line and Battery |
|
4.1.13.4.2.4 CommEn Short to 14V |
Monitor the CAN & WakeUp line when short between the communication enable line and Battery(14V) and Removed the fault |
Acceptance Criteria: The DUT shall resume normal communication without any operator intervention within 300 ms after the fault is removed. |
4.1.13.4.2.4 CommEn Short to 18V |
Monitor the CAN & WakeUp line when short between the communication enable line and Battery(18V) and Removed the fault |
Acceptance Criteria: The DUT shall resume normal communication without any operator intervention within 300 ms after the fault is removed. |
4.1.13.4.2.4 CommEn Short to 26.5V |
Monitor the CAN & WakeUp line when short between the communication enable line and Battery(26.5V)and Removed the fault |
Acceptance Criteria: The DUT shall resume normal communication without any operator intervention within 300 ms after the fault is removed. |
GMW14241 DWCAN TestCases
No Internal Termination TestCases